This video shows a thoracus-copic repair of an H type fistula in a three-month-old infant. The infant, who had multiple medical issues, had recurrent aspiration in an upper GI, which showed an H fistula. Here you see a bronchoscopy demonstrating that fistula. There were two attempts at endoluminal ablation. For this thoracus-copic approach, the patient was placed in a modified lateral tube disposition with the patient rolled prone of approximately 45 degrees. 3 ports were used, a 4 and 2-3s, 1-3 later advanced to a 5. Here you see the fistula again at Richard Broncoschepi at the beginning of the procedure. 4mm 30-degree lens was used for the procedure and was placed behind the tip of the scapula. The procedure is started up in the apex and the 3mm vessel sealer is used for a deception and to open the pura up in the apex. Careful dissection is used to identify the esophagus and the…

Show the full transcript

This video shows a thoracus-copic repair of an H type fistula in a three-month-old infant. The infant, who had multiple medical issues, had recurrent aspiration in an upper GI, which showed an H fistula. Here you see a bronchoscopy demonstrating that fistula. There were two attempts at endoluminal ablation. For this thoracus-copic approach, the patient was placed in a modified lateral tube disposition with the patient rolled prone of approximately 45 degrees. 3 ports were used, a 4 and 2-3s, 1-3 later advanced to a 5. Here you see the fistula again at Richard Broncoschepi at the beginning of the procedure. 4mm 30-degree lens was used for the procedure and was placed behind the tip of the scapula. The procedure is started up in the apex and the 3mm vessel sealer is used for a deception and to open the pura up in the apex. Careful dissection is used to identify the esophagus and the trachea. Gradually a plane is developed between the esophagus and the trachea, below the level of the fistula. This is an important maneuver in helping safely separate the two before the varied adherent area between the two structures is encountered. In this particular case, we did not put a catheter across the H type fistula, as we felt confident we would identify it. But occasionally this can be helpful. The section is continued inferiorly, and a small bridge of tissue, which initially was thought to be the fistula, but later was clearly just adhering connected tissue was divided. In this case, a 3-millimeter hook cotter was used to pull on the fibers and separate them around away from critical structure. With the area of the fistula encountered, the section was carried out above the fistula so that a retro fistula plane could be developed. Using the 3mm Maryland and later a 5mm hook, an instrument was passed around behind the fistula, taking care to not injure the esophagus or the membranous portion of the fistula. where you can see the right angle hook, right angle instrument being passed behind the fistula. The tips are visualized and then a two-row silk is passed around the fistula to help with retraction. Previously, we have divided the fistula and then over sewn the two ends. In this case, the child was large enough and now with the availability of a five-millimeter staper, the decision was made to use this to divide the fistula. was taken to make sure that the recurrent laryngeal nerve and other important structures were not within the field of deception. The lower port, which was in the posterior axillary line, was in large 2-5, and the 5-millimeter stapler was inserted, and the 2-0 silk was used to help retract the fistula to allow for insertion of the stapler. The silk was then removed, and a single application of the 5-millimeter staper was used. This divided the fistula, placing two rows of staples on either side, and there was no evidence of any incomplete division or other issues. Portion of apical fat was then taken and sewn down to cover the esophageal end of the staper line to help separate the two staper lines to try and prevent recurrent fistulization. With this portion of the procedure completed, the pleura was closed over the divided fistula in case there was a leak so that it would remain contained. Here you see the closed pleura. The lung was re-expanded and no chest tube was left. Here you see the patient two weeks post-opatively and the fist tour at 3 months.

Transcript made automatically from the video’s sound; it may contain errors.

More Thoracic surgery videos

All Thoracic surgery videos