Transcript
Here we describe the laparoscopic multi-port inguinal hernia repair in a male newborn. The patient is placed supine. For a left-sided inguinal hernia, the surgeon is standing relatively high up next to the head on the right side. The patient's head is turned to the left to keep the surgeon's arm and the tube out of each other's way. A 5mm camera port is placed at the belly button using the Hassan technique. 2-3mm working ports are placed as shown. In small infants, these should be placed as high up and as laterally as possible. The needle is inserted into the abdomen through the camera port. Alternatively, a transoptional wall stitch may be performed. The vast and the testicular vessels come together as an inverted V at the inner ingonal ring with the vessels being laterally and the vast being medially. The right-handed needle driver grasps the suture about 1 cm proximal to the needle…
Show the full transcript
Here we describe the laparoscopic multi-port inguinal hernia repair in a male newborn. The patient is placed supine. For a left-sided inguinal hernia, the surgeon is standing relatively high up next to the head on the right side. The patient's head is turned to the left to keep the surgeon's arm and the tube out of each other's way. A 5mm camera port is placed at the belly button using the Hassan technique. 2-3mm working ports are placed as shown. In small infants, these should be placed as high up and as laterally as possible. The needle is inserted into the abdomen through the camera port. Alternatively, a transoptional wall stitch may be performed. The vast and the testicular vessels come together as an inverted V at the inner ingonal ring with the vessels being laterally and the vast being medially. The right-handed needle driver grasps the suture about 1 cm proximal to the needle. Then the left-handed needle driver grasps the needle between this and middle-third. The orientation of the needle can then be adjusted in the three-dimensional space. When the needle has the correct orientation, the right-handed needle driver grasps the needle between proximal and middle-third. After incision of the plutonium craniolaterally, at the inner inguinal ring, the first stitch is performed. I prefer a first-ring suture with the first stitch outside in at about 9 o'clock on the left and 3 o'clock at the right inner inguinal ring. In order to keep the orientation of the needle, the left-handed needle driver holds the needle in place while the right-handed needle driver pulls at the suture. We use a non-absorbable 4-0 polyfilament tychron suture with the small needle. The next stitch is made inside out. Adjustments of the three-dimensional orientation of the needle may be performed as shown. The next stitch is made at the medial side of the inner inguinal ring, taking care not to harm the inferior epigastic vessels. Throw and subunating the surgeon's wrist helps to get in the correct plane and to use the given rotation of the needle with minimal harm to the tissue. A next stitch is performed just immediately to the vest without injuring the vest. Next the peritonium between vest and testicular vessels is pulled up and the stitch is performed without injuring these structures. A last inside out stitch is performed lateral to the testicular vessels grabbing more tissue to complete the perstring suture. In a female the perstring is likewise performed. The inferior epigastic vessels are the only structures at risk. The round ligament should be included in the perstring suture. We use a sliding knot to pull the perstrings together. The suture end containing the needle and the suture part coming out of the tissue during the last stitch are pulled apart 180 degrees in order to make the knot sliding. Then the knot is slided and the perstring pulled together. The knot is fixed in place by pulling the free-ending suture end. Per the knots are made as shown. It is important to have the suture held by the right-handed needle driver and the left-handed needle driver as parallel as possible. The suture is given to the right-hand and kept parallel to the left-handed needle driver. The suture is then cut. Working ports are removed on a direct vision. The camera port is removed and the periombilical fascia is closed using interrupted trio No vichels, sutures.
Transcript made automatically from the video’s sound; it may contain errors.
More Abdominal wall and groin videos
Hiatus Hernia repairOperative video · 21 min
internal hernia secondary to Meckel diverticulum operative treatmentOperative video · 1 min
Laparoscopic non-mesh inguinal hernia repair using the Patkowski techniqueOperative video · 9 min
Percutaneous medial approach to right inguinal hernia repairOperative video · 5 min
lap inguinal hernia repair: video 28Operative video · 10 min
lap inguinal hernia repair: video 24Operative video · 6 min
lap inguinal hernia repair: video 23Operative video · 4 min
lap inguinal hernia repair: video 22Operative video · 2 min
Laparoscopic single port percutaneous pediatric inguinal hernia repair: video 20Operative video · 5 min
Laparoscopic single port percutaneous pediatric inguinal hernia repair: video 32Operative video · 41 min
Laparoscopic single port percutaneous pediatric inguinal hernia repair: video 21Operative video · 21 min
Laparoscopic single port percutaneous pediatric inguinal hernia repair: video 6Operative video · 11 min