Thoracoscopic repair of pure esophageal atresia

Operative videoThoracic surgery18 minCaptions
Thoracoscopic repair of pure esophageal atresia – Operative video video▶ Watch in PSC Videos

Watch the video Discuss in the forum

Watching needs a free PSC account; some videos are for PSC Pro members.

About this video

Shared in the PSC forum topic “Thoracoscopic repair of pure esophageal atresia” (Esophageal atresia & TOF).

Forum topic: Thoracoscopic repair of pure esophageal atresia in Esophageal atresia & TOF.

Transcript

A full-term baby weighing 2.8 kilograms was diagnosed with pure esophageal atreasure. No other associated anomalies were found. The nasogastric tube inserted, failed to pass into the stomach and coiled the upper pouch. Plain film showed an airless abdomen. The patient was placed in a prone position at the edge of the operating table as described by a professor Darius Patkowski. Using the open technique, a 5mm 30-degree angle scope was inserted, one finger's breadth or two into coastal spaces below the lower angle of the scapula. A new mothorax was then established by carbon dioxide in deflation, at a working pressure of 5-6mm in mercury. Two three-millimeter working ports were also inserted under camera control. The first ported in the same coastal space as the camera port, three centimeters from the power-vertrable line, and the second port as high as possible in the axilla in the…

Show the full transcript

A full-term baby weighing 2.8 kilograms was diagnosed with pure esophageal atreasure. No other associated anomalies were found. The nasogastric tube inserted, failed to pass into the stomach and coiled the upper pouch. Plain film showed an airless abdomen. The patient was placed in a prone position at the edge of the operating table as described by a professor Darius Patkowski. Using the open technique, a 5mm 30-degree angle scope was inserted, one finger's breadth or two into coastal spaces below the lower angle of the scapula. A new mothorax was then established by carbon dioxide in deflation, at a working pressure of 5-6mm in mercury. Two three-millimeter working ports were also inserted under camera control. The first ported in the same coastal space as the camera port, three centimeters from the power-vertrable line, and the second port as high as possible in the axilla in the third or fourth intercostal space. Gentle blunt dissection is carried out with 3mm marine forceps and a fenestrated single-action grasper. A thin fibro-strand was found connecting both ends of the esophagus. The azygos vein was left intact. The lower pouch is dissected, preserving the vascular branches from the aorta and dissecting in between them. This is measured between both ends of 4 vertebral bodies or approximately 4cm. The first posterior stitch is made using Vycro 5-0 and Tumble Square Slining Nots. A six French nasogastric tube is passed. The enastomosis is completed.

Transcript made automatically from the video’s sound; it may contain errors.

More Thoracic surgery videos

All Thoracic surgery videos