Laparoscopic duodenal atresia repair with a 5 mm endoscopic stapler
Watch the video Discuss in the forum
Watching needs a free PSC account; some videos are for PSC Pro members.
About this video
Shared in the PSC forum topic “Laparoscopic duodenal atresia repair with 5mm endoscopic stapler” (GI obstruction).
Forum topic: Laparoscopic duodenal atresia repair with 5mm endoscopic stapler in GI obstruction.
Transcript
We present a laparoscopic repair of Deuidino Latreja using a 5mm endoscopic stapler. We have no disclosures. An X-36-week male is born with suspected Deuidino Latreja based on prenatal ultrasound. This diagnosis is confirmed on KUB with air only in the stomach and proximal Deuidino with no distal bowel gas pattern. He was subsequently taken to the OR on Day of Life 3. He's positioned perpendicular to the length of the OR table adjacent to anesthesia with the monitor at the patient's head and the surgeons at the patient's feet. A 5-millimeter port was placed in the umbilicus for a camera and two stab incisions were placed in the right and left mid-quadrance. One trans-abdominal suture was placed for liver retraction. We then proceeded with co-curization of the duodenum. Once we have mobilized the duodenum, we placed enteradames in the proximal and distal portions of the duodenum. Another…
Show the full transcript
We present a laparoscopic repair of Deuidino Latreja using a 5mm endoscopic stapler. We have no disclosures. An X-36-week male is born with suspected Deuidino Latreja based on prenatal ultrasound. This diagnosis is confirmed on KUB with air only in the stomach and proximal Deuidino with no distal bowel gas pattern. He was subsequently taken to the OR on Day of Life 3. He's positioned perpendicular to the length of the OR table adjacent to anesthesia with the monitor at the patient's head and the surgeons at the patient's feet. A 5-millimeter port was placed in the umbilicus for a camera and two stab incisions were placed in the right and left mid-quadrance. One trans-abdominal suture was placed for liver retraction. We then proceeded with co-curization of the duodenum. Once we have mobilized the duodenum, we placed enteradames in the proximal and distal portions of the duodenum. Another trans-abdominal stitch was placed through the enteradames to align the two limbs. The camera was placed through a stavincision, and the 5mm stapler placed through the port. The stapler was inserted and fired to create the inestimosis. The enteradame was closed with multiple interrupted sutures. The trans-abdominal suture was then cut and then tied down. Post operatively, the baby was kept NPO until post-op day 5. An upper GI confirmed no leak with passage of contrast into the distal bowel. The baby's diet was then advanced, and he was discharged home on post-operative day 10.
Transcript made automatically from the video’s sound; it may contain errors.
More Neonatal surgery videos
Open repair of neonatal ileal atresiaOperative video · 36 min
Duodenal atresia and stenosis technical details lecture: video 2Clinical discussion · 8 min
Duodenal atresia and stenosis technical details lecture: video 4Clinical discussion · 21 min
Duodenal atresia and stenosis technical details lecture: video 6Clinical discussion · 9 min
Duodenal atresia and stenosis technical details lecture: video 7Clinical discussion · 10 min
Duodenal atresia and stenosis technical details lecture: video 5Clinical discussion · 9 min
Laparoscopic Duodeno-duodenostomy for Duodenal AtresiaOperative video · 45 min
Laparoscopic management of duodenal atresia: video 3Operative video · 6 min
Laparoscopic management of duodenal atresia: video 9Operative video · 8 min
Laparoscopic management of duodenal atresia: video 2Operative video · 4 min
open Duodeno-duodenostomy for Duodenal AtresiaOperative video · 30 min
Laparoscopic repair of a congenital Morgagni-Larrey bilateral diaphragmatic hernia: video 13Operative video · 6 min